UpdatedDec 8, 2025
PublishedAug 17, 2024
Packagecom.ahsim.raschetrgk
MD56d1d56a80ebdac8f1d193b2ea3008303
SHA1 (signer)00:CD:68:2D:98:5C:A6:F5:35:A0:5B:B4:24:58:4C:A4:8C:30:95:03
Signed byCN=Mikhail Stepanov
Malware scanTRUSTED
Contact[email protected]
What's new
List of changes in the new version:
- fixed calculation of exposure time if the unit of activity GBk is selected in the settings
- now the time is calculated as in the old application, fixed calculation for different densities of blackening
If you find errors, write to me by email
- fixed calculation of exposure time if the unit of activity GBk is selected in the settings
- now the time is calculated as in the old application, fixed calculation for different densities of blackening
If you find errors, write to me by email
Description
The program is developed to calculate the exposure time for radiographic inspection using industrial source of ionizing radiation Iridium-192.
To calculate the exposure time set:
- The current activity in Ci
- Radiation thickness in mm;
- Focal length in mm.
And also select the type of film, blackening density and controlled material.
Current activity is calculated automatically if source data is entered: initial activity and estimated date of receipt. You can specify no more than five sources in the program.
Knowing the half-life of the Iridium-192 isotope, which is 74.4 days, the current activity is calculated.
Using known data about the controlled object (standard size, category of welded joint), it is possible to calculate the focal length, as well as the number of controlled areas.
If you find any errors or have any suggestions for further development of the program, write to me by email.
Exposure time calculations are experimental and may not meet your specifications.
(text translated by Google Translate)
To calculate the exposure time set:
- The current activity in Ci
- Radiation thickness in mm;
- Focal length in mm.
And also select the type of film, blackening density and controlled material.
Current activity is calculated automatically if source data is entered: initial activity and estimated date of receipt. You can specify no more than five sources in the program.
Knowing the half-life of the Iridium-192 isotope, which is 74.4 days, the current activity is calculated.
Using known data about the controlled object (standard size, category of welded joint), it is possible to calculate the focal length, as well as the number of controlled areas.
If you find any errors or have any suggestions for further development of the program, write to me by email.
Exposure time calculations are experimental and may not meet your specifications.
(text translated by Google Translate)
Required features
- Faketouch android.hardware.faketouch
- Screen Portrait android.hardware.screen.portrait
Permissions (9)
Calculation RGC requests the following Android permissions:
- Access Adservices Ad Id android.permission.ACCESS_ADSERVICES_AD_ID
- Access Adservices Attribution android.permission.ACCESS_ADSERVICES_ATTRIBUTION
- Access Adservices Topics android.permission.ACCESS_ADSERVICES_TOPICS
- Access Network State android.permission.ACCESS_NETWORK_STATE
- Foreground Service android.permission.FOREGROUND_SERVICE
- Internet android.permission.INTERNET
- Vibrate android.permission.VIBRATE
- Wake Lock android.permission.WAKE_LOCK
- Gms Permission Ad Id com.google.android.gms.permission.AD_ID