SCADAfeathery for Modbus APK
Version V 3.1.0.0 - com.automationservices.scadafeatheryautomationservices,scadafeathery,productivity
SCADA with simple handling for modbus-networks, optimized for WAGO-Devices.
APP Information
Download Version | V 3.1.0.0 (10) |
Apk Size | 4.80 MB |
App Developer | AutomationServices |
Malware Check | UNKNOWN |
Install on Android | and up |
App Package | com.automationservices.scadafeathery.apk |
MD5 | 0561d6e2af8276932f4bd386909d127a |
Rate | 5 |
Table of Contents
Download SCADAfeathery for Modbus V 3.1.0.0 APK
App Description
SCADAfeathery for Modbus is automationservices,scadafeathery,productivity, content rating is Everyone (PEGI-3). This app is rated 5 by 1 users who are using this app. To know more about the company/developer, visit AutomationServices website who developed it. com.automationservices.scadafeathery.apk apps can be downloaded and installed on Android and higher Android devices. The Latest Version of V 3.1.0.0 Available for download. Download the app using your favorite browser and click Install to install the application. Please note that we provide both basic and pure APK files and faster download speeds than APK Mirror. This app APK has been downloaded 2+ times on store. You can also download com.automationservices.scadafeathery APK and run it with the popular Android Emulators.
You have a Modbus device and want to visualize it by a few easy steps? Are you an owner of WAGO (P-)FC series 750758? Are your writing CoDeSys 2.3 programms on WAGO-devices and want to see the calculation results on your android device? Then this application is that what you are looking for. After only 3 steps the definition of the visualization is complete: 1) Define your Modbus network. 2) Create data points. 3) Define the representation of the data points You can define any number of devices on the network. The devices (called network services) are stored in the application, and can be used later. For each device (network service), you can assign its data points. The definition of a datapoint consists of the following parameters: - Designation of the datapoint - Datatype of the datapoint (based on IEC61131-Datatypes) - Datatype STRING requiers the length in bytes additionaly - Read-Defintion: FC-Code (FC1, FC2, FC3, FC4) - Read-Definition: modbus address (register or coil, depends on FC-Code) - Read-Definition: bit offset, within the addressed modbus register or coil - Write-Defintion: FC-Code (FC5, FC6, FC15, FC16) - Write-Definition: modbus address (register or coil, depends on FC-Code) - Write-Definition: bit offset, within the addressed modbus register or coil For WAGO-Devices this parameters are filled out automaticaly. Each data point can be visualized by (at the moment) 4 presentation items: + Textbox + Slider (0..100) + Switch + XY-Plot Your are able to scale the values by the linear polynom (f(x)=m*x+b). You can define minmax-ranges, that are monitored at the runtime. There is a constant monitoring of the data point availability , you will be notified if the datapoint is not accessable anymore. Modbus-communication The communication is possible through Wifi and 3G4G- Networks. Following modbus function codes are supported: FC1, FC2, FC3, FC4,FC5,FC6,FC15,FC16. An real-time algorithm used for communication task guarantees that the calculated cycle-time for each communication-job will be kept. The cycle-time is linearly proportional to the number of datapoints within the perspective. Special features for WAGO-Devices This appliation contains a database with all at the moment existing WAGO-Controllers and Couplers of the series 750758. There is also modbus process image data about all terminals of the series 750753. You have defined your WAGO node already as network service? Then mark the discovered devices as WAGO device and scan the node. The connected terminals will be recognized and the full process image for modbus will be stored. Now you no longer have to calculate the address of the terminal in the process image. Just select the terminal and the channel of the terminal from the node description and make it to a data point. Do you have a PFC (programmable WAGO coupler)? Then it is possible to you to define a datapoint just by entereing of the IEC61131-address. Just enter the %I, %Q, %M address of your programm variable and the application converts this information into accoridn modbus-address on the network. Hint: Consider the PI-Assignment-Setting from CoDeSys if you want the write-access to kbus-terminals.
App ChangeLog
- Version 2.0.1
- Bugfix within the main menu carousel for Jelly Bean.
- Version 2.0.0
- New functions:
- - Modbus-Access, Read/Write Now the user is able to define his modbus communications more freely.
- - Splashscreen
- - Support for additional WAGO-Devices (750-885, 750-493, 750-635, 750-657..)
- - New licensing-model: Subscription support
- Bugfixes:
- - Bugfix Real-Values, formatting